 	{"id":304,"date":"2024-12-11T08:32:15","date_gmt":"2024-12-11T08:32:15","guid":{"rendered":"https:\/\/app.medseven.pl\/?post_type=produkty&#038;p=304"},"modified":"2025-11-20T13:50:50","modified_gmt":"2025-11-20T12:50:50","slug":"aparat-do-bezdechu-sennego-sefam-s-box-autocpap","status":"publish","type":"produkty","link":"https:\/\/app.medseven.pl\/index.php\/produkty\/aparat-do-bezdechu-sennego-sefam-s-box-autocpap\/","title":{"rendered":"Aparat do bezdechu sennego SEFAM S.BOX &#8211; autocpap"},"content":{"rendered":"","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"kategoria":[11,24,26],"producent":[],"class_list":["post-304","produkty","type-produkty","status-publish","hentry","kategoria-aparatura-medyczna","kategoria-aparaty-cpap","kategoria-aparaty-autocpap"],"acf":{"kategoria":[11,24,26],"zdjecie_podstawowe":595,"ident":"99647","producent":46,"model":"S.BOX","opis":"AUTO CPAP S.BOX firmy SEFAM to nowoczesne urz\u0105dzenie do leczenia obturacyjnego bezdechu sennego i innych zaburze\u0144 oddechowych podczas snu. Wyposa\u017cone w inteligentne funkcje, to proste w obs\u0142udze urz\u0105dzenie zapewnia komfortow\u0105 terapi\u0119 snu. Oto kilka kluczowych cech tego urz\u0105dzenia:\r\n<strong>Nowoczesny wygl\u0105d:<\/strong>\u00a0AUTO CPAP S.BOX ma nowoczesny design, kt\u00f3ry pasuje do nowoczesnych sypialni i zapewnia estetyczny wygl\u0105d.\r\n<strong>Prosta obs\u0142uga:<\/strong>\u00a0Urz\u0105dzenie jest \u0142atwe w obs\u0142udze, co sprawia, \u017ce \u200b\u200bjest przyjazne dla pacjent\u00f3w.\r\n<strong>Automatyczne dostosowywanie ci\u015bnienia:<\/strong>\u00a0AUTO CPAP S.BOX automatycznie dostosowuje i reguluje ci\u015bnienie dostarczane przez urz\u0105dzenie zgodnie z indywidualnymi potrzebami pacjenta. To oznacza, \u017ce nie trzeba r\u0119cznie dostosowywa\u0107 ci\u015bnienia.\r\n<strong>Reakcja na zaburzenia snu:<\/strong> Urz\u0105dzenie reaguje na r\u00f3\u017cne zaburzenia snu, w tym ograniczenie przep\u0142ywu i chrapanie, dostosowuj\u0105c terapi\u0119 w czasie rzeczywistym.\r\n<strong>Inteligentna funkcja Ramp:<\/strong>\u00a0Funkcja Ramp wykrywa moment za\u015bni\u0119cia pacjenta i dostosowuje ci\u015bnienie, aby u\u0142atwi\u0107 pacjentowi rozpocz\u0119cie terapii.","specyfikacja":"<p data-start=\"40\" data-end=\"98\"><strong data-start=\"40\" data-end=\"98\">Specyfikacja techniczna aparatu CPAP Sefam S.Box Auto:<\/strong><\/p>\r\n\r\n<ul data-start=\"100\" data-end=\"1342\">\r\n \t<li data-start=\"100\" data-end=\"169\">\r\n<p data-start=\"102\" data-end=\"169\"><strong data-start=\"102\" data-end=\"121\">Typ urz\u0105dzenia:<\/strong> Auto CPAP (automatyczne dostosowanie ci\u015bnienia)<\/p>\r\n<\/li>\r\n \t<li data-start=\"170\" data-end=\"231\">\r\n<p data-start=\"172\" data-end=\"231\"><strong data-start=\"172\" data-end=\"193\">Zakres ci\u015bnienia:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">4\u201320 cm H\u2082O, regulacja co 0,5 cm H\u2082O<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"232\" data-end=\"290\">\r\n<p data-start=\"234\" data-end=\"290\"><strong data-start=\"234\" data-end=\"252\">Poziom ha\u0142asu:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">oko\u0142o 26 dB(A)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"291\" data-end=\"365\">\r\n<p data-start=\"293\" data-end=\"365\"><strong data-start=\"293\" data-end=\"327\">Maksymalny przep\u0142yw powietrza:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">180 l\/min przy 20 cm H\u2082O (bez nawil\u017cacza, z przewodem 15 mm)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"366\" data-end=\"437\">\r\n<p data-start=\"368\" data-end=\"437\"><strong data-start=\"368\" data-end=\"397\">Wymiary (bez nawil\u017cacza):<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">24,5 \u00d7 14 \u00d7 11 cm<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"438\" data-end=\"489\">\r\n<p data-start=\"440\" data-end=\"489\"><strong data-start=\"440\" data-end=\"449\">Waga:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">1,4 kg (z nawil\u017caczem: 1,7 kg)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"490\" data-end=\"547\">\r\n<p data-start=\"492\" data-end=\"547\"><strong data-start=\"492\" data-end=\"507\">Czas rampy:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">od 0 do 45 minut lub tryb iRamp (inteligentny start)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"548\" data-end=\"604\">\r\n<p data-start=\"550\" data-end=\"604\"><strong data-start=\"550\" data-end=\"564\">Zasilanie:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">24 V DC (zasilacz zewn\u0119trzny)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"605\" data-end=\"662\">\r\n<p data-start=\"607\" data-end=\"662\"><strong data-start=\"607\" data-end=\"622\">Pob\u00f3r mocy:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">do 25 W (bez nawil\u017cacza), do 75 W (z nawil\u017caczem)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"663\" data-end=\"716\">\r\n<p data-start=\"665\" data-end=\"716\"><strong data-start=\"665\" data-end=\"676\">Pami\u0119\u0107:<\/strong> <span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\">karta SD (365 dni danych terapeutycznych)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"717\" data-end=\"1138\">\r\n<p data-start=\"719\" data-end=\"742\"><strong data-start=\"719\" data-end=\"742\">Funkcje komfortowe:<\/strong><\/p>\r\n\r\n<ul data-start=\"745\" data-end=\"1138\">\r\n \t<li data-start=\"745\" data-end=\"786\">\r\n<p data-start=\"747\" data-end=\"786\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"9\" data-is-only-node=\"\">iRamp<\/strong> \u2013 automatyczne przej\u015bcie do trybu Auto-CPAP po za\u015bni\u0119ciu<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"789\" data-end=\"830\">\r\n<p data-start=\"791\" data-end=\"830\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"17\" data-is-only-node=\"\">Mask Fit &amp; Go<\/strong> \u2013 szybka kontrola dopasowania maski i wykrywanie przecieku<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"833\" data-end=\"874\">\r\n<p data-start=\"835\" data-end=\"874\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"15\" data-is-only-node=\"\">Mask Select<\/strong> \u2013 precyzyjne obliczanie niezamierzonych przeciek\u00f3w<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"877\" data-end=\"918\">\r\n<p data-start=\"879\" data-end=\"918\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"12\" data-is-only-node=\"\">CC+ Mode<\/strong> \u2013 3 poziomy komfortu dostosowuj\u0105ce ci\u015bnienie do fazy oddechu<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"921\" data-end=\"962\">\r\n<p data-start=\"923\" data-end=\"962\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"18\" data-is-only-node=\"\">Circuit Select<\/strong> \u2013 automatyczne dopasowanie do oporu uk\u0142adu oddechowego (\u015brednica przewodu, d\u0142ugo\u015b\u0107, typ maski)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"965\" data-end=\"1006\">\r\n<p data-start=\"967\" data-end=\"1006\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"33\" data-is-only-node=\"\">Adaptive Thermo Control (ATC)<\/strong> \u2013 automatyczne ustawienie podgrzewanego przewodu w zale\u017cno\u015bci od ustawie\u0144 nawil\u017cacza<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"1009\" data-end=\"1050\">\r\n<p data-start=\"1011\" data-end=\"1050\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"18\" data-is-only-node=\"\">Humid Control+<\/strong> \u2013 nawil\u017canie bez kondensacji, uwzgl\u0119dniaj\u0105ce temperatur\u0119 otoczenia i \u015bredni przep\u0142yw powietrza<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"1053\" data-end=\"1094\">\r\n<p data-start=\"1055\" data-end=\"1094\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"21\" data-is-only-node=\"\">Intelligent Start<\/strong> \u2013 automatyczne rozpocz\u0119cie terapii po wykryciu oddechu<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"1097\" data-end=\"1138\">\r\n<p data-start=\"1099\" data-end=\"1138\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"13\" data-is-only-node=\"\">Wave &amp; Go<\/strong> \u2013 aktywacja ekranu za pomoc\u0105 prostego ruchu r\u0119ki<\/span><\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"1139\" data-end=\"1342\">\r\n<p data-start=\"1141\" data-end=\"1171\"><strong data-start=\"1141\" data-end=\"1171\">\u0141\u0105czno\u015b\u0107 i telemonitoring:<\/strong><\/p>\r\n\r\n<ul data-start=\"1174\" data-end=\"1342\">\r\n \t<li data-start=\"1174\" data-end=\"1215\">\r\n<p data-start=\"1176\" data-end=\"1215\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"16\" data-is-only-node=\"\">SEFAM Access<\/strong> \u2013 aplikacja mobilna dla pacjenta (iOS\/Android)<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"1218\" data-end=\"1259\">\r\n<p data-start=\"1220\" data-end=\"1259\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"17\" data-is-only-node=\"\">SEFAM Connect<\/strong> \u2013 platforma do zdalnego monitorowania terapii<\/span><\/p>\r\n<\/li>\r\n \t<li data-start=\"1262\" data-end=\"1342\">\r\n<p data-start=\"1264\" data-end=\"1342\"><span class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"><strong data-start=\"0\" data-end=\"45\" data-is-only-node=\"\">Kompatybilno\u015b\u0107 z urz\u0105dzeniami pomiarowymi<\/strong> \u2013 ci\u015bnienie krwi, waga, aktywno\u015b\u0107 fizyczna, saturacja, t\u0119tno (urz\u0105dzenia sprzedawane osobno)<\/span><\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>","instrukcje":534,"media":"","wideo":null,"kody":[{"kod_serwisowy":"Powietrze podawane przez urz\u0105dzenie jest zbyt ciep\u0142e.","rozwiazanie":"Filtry wlotu powietrza s\u0105 zanieczyszczone. Zatkany wlot powietrza. Temperatura pomieszczenia jest zbyt wysoka.\r\nOczy\u015bci\u0107 lub wymieni\u0107 filtry (patrz rozdzia\u0142 \u201eCzyszczenie i konserwacja\u201d na stronie 30). Odsun\u0105\u0107 od aparatu wszelk\u0105 po\u015bciel lub odzie\u017c. Obni\u017cy\u0107 temperatur\u0119 w pomieszczeniu. Upewni\u0107 si\u0119, czy aparat jest oddalony od wszelkich \u017ar\u00f3de\u0142 ciep\u0142a. Od\u0142\u0105czy\u0107 przew\u00f3d grzewczy (je\u015bli zainstalowano S.Box heated tube with ATC [rura podgrzewana]).","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Aparat nie wy\u015bwietla prawid\u0142owego ci\u015bnienia na wy\u015bwietlaczu.","rozwiazanie":"W\u0142\u0105czona jest funkcja narastania ci\u015bnienia.  Wybrane narastanie nie jest odpowiednie dla pacjenta.\r\nNale\u017cy sprawdzi\u0107, czy wy\u015bwietlany jest wska\u017anik funkcji narastania. Je\u015bli to konieczne, nale\u017cy wy\u0142\u0105czy\u0107 funkcj\u0119 narastania (patrz rozdzia\u0142 \u201eJak zmieni\u0107 ustawienia urz\u0105dzenia\u201d na stronie 16). Skontaktowa\u0107 si\u0119 z osob\u0105 \u015bwiadcz\u0105c\u0105 us\u0142ugi opieki zdrowotnej w miejscu zamieszkania pacjenta.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Aparat nie dzia\u0142a prawid\u0142owo lub wydaje si\u0119 uszkodzony.","rozwiazanie":"Nadmierne zak\u0142\u00f3cenia elektromagnetyczne.  Oddali\u0107 aparat od \u017ar\u00f3de\u0142 zak\u0142\u00f3ce\u0144 takich jak lampy halogenowe, telefony przeno\u015bne itp.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Dyskomfort zwi\u0105zany z uczuciem zbyt du\u017cego ci\u015bnienia.","rozwiazanie":"Ci\u015bnienie aparatu.  Aparat jest ustawiony w trybie Auto-CPAP.\r\nAdaptacja do zwi\u0119kszonego ci\u015bnienia w drogach oddechowych trwa pewien czas. Nale\u017cy spr\u00f3bowa\u0107 skorzysta\u0107 z funkcji narastania ci\u015bnienia podczas zasypiania (patrz rozdzia\u0142 \u201eNarastanie ci\u015bnienia\u201d na stronie 12). Nale\u017cy zrelaksowa\u0107 si\u0119 i powoli oddycha\u0107 przez nos. Poziom ci\u015bnienia zosta\u0142 przepisany przez lekarza i mo\u017ce by\u0107 zmieniony tylko na jego zlecenie. W przypadku odczucia, \u017ce podawane ci\u015bnienie si\u0119 zmieni\u0142o, nale\u017cy skontaktowa\u0107 si\u0119 z osob\u0105 \u015bwiadcz\u0105c\u0105 us\u0142ugi opieki zdrowotnej w miejscu zamieszkania pacjenta w celu sprawdzenia ci\u015bnienia.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Nawr\u00f3t wcze\u015bniej wyst\u0119puj\u0105cych objaw\u00f3w zespo\u0142u bezdechu sennego.","rozwiazanie":"Aparat nie zosta\u0142 ustawiony na prawid\u0142owe ci\u015bnienie lub nie funkcjonuje prawid\u0142owo. Nast\u0105pi\u0142a zmiana stanu fizycznego u\u017cytkownika lub zapotrzebowania na ci\u015bnienie.\r\nPoprosi\u0107 osob\u0119 \u015bwiadcz\u0105c\u0105 us\u0142ugi opieki zdrowotnej w miejscu zamieszkania pacjenta o sprawdzenie dzia\u0142ania aparatu. Skontaktowa\u0107 si\u0119 z lekarzem prowadz\u0105cym.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Aparat nie w\u0142\u0105cza si\u0119 (brak wy\u015bwietlania).","rozwiazanie":"Modu\u0142 zasilania nie jest w\u0142a\u015bciwie pod\u0142\u0105czony. Brak napi\u0119cia w sieci. Przepalony bezpiecznik aparatu.\r\nNale\u017cy sprawdzi\u0107 po\u0142\u0105czenia pomi\u0119dzy aparatem,\r\nmodu\u0142em zasilania i gniazdem sieciowym.\r\nU\u017cy\u0107 innego urz\u0105dzenia (np.: lampki, radia itp.), aby\r\nsprawdzi\u0107, czy gniazdko elektryczne dzia\u0142a.\r\nSkontaktowa\u0107 si\u0119 z osob\u0105 \u015bwiadcz\u0105c\u0105 us\u0142ugi opieki\r\nzdrowotnej w miejscu zamieszkania pacjenta.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"W zbiorniku pojawia si\u0119 bia\u0142y osad.","rozwiazanie":"Jest to kamie\u0144 pochodz\u0105cy z wody wodoci\u0105gowej.\r\nUsun\u0105\u0107 osad za pomoc\u0105 g\u0105bki i p\u0142ynu do zmywania\r\nnaczy\u0144. Pozostawi\u0107 zbiornik w roztworze\r\nsk\u0142adaj\u0105cym si\u0119 z jednej cz\u0119\u015bci octu i 9 cz\u0119\u015bci wody\r\n(patrz rozdzia\u0142 \u201eCzyszczenie i konserwacja\u201d na\r\nstronie 30). Dok\u0142adnie op\u0142uka\u0107 du\u017c\u0105 ilo\u015bci\u0105 wody z\r\nkranu. Wytrze\u0107 powierzchni\u0119 zewn\u0119trzn\u0105 czyst\u0105\r\n\u015bciereczk\u0105.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"W obwodzie pacjenta, w przewodzie grzewczym lub w masce pojawiaj\u0105 si\u0119 kropelki wody.","rozwiazanie":"Kilka kropelek wody jest zjawiskiem normalnym, szczeg\u00f3lnie w zimie. Poziom wody w zbiorniku (je\u017celi wyst\u0119puje) jest zbyt wysoki. Nadmierna kondensacja pary wodnej.\r\nZmniejszy\u0107 poziom nawil\u017cania (patrz rozdzia\u0142 \u201eJak zmieni\u0107 ustawienia urz\u0105dzenia\u201d na stronie 16). Nale\u017cy sprawdzi\u0107, czy poziom wody w zbiorniku nie przekracza poziomu maksymalnego. W razie potrzeby usun\u0105\u0107 nadmiar wody. U\u0142o\u017cy\u0107 przew\u00f3d do oddychania pod po\u015bciel\u0105.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Na aparat zosta\u0142a rozlana woda.","rozwiazanie":"Od\u0142\u0105czy\u0107 aparat i pozostawi\u0107 go do osuszenia na co najmniej 24 godziny. Ponownie pod\u0142\u0105czy\u0107 i sprawdzi\u0107, czy dzia\u0142a prawid\u0142owo.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Temperatura przewodu grzewczego jest zbyt niska.","rozwiazanie":"Moc grzewcza przewodu jest ustawiona na OFF.  Ustawi\u0107 warto\u015b\u0107 mocy grzewczej mi\u0119dzy 01 a 05 (patrz rozdzia\u0142 \u201eJak zmieni\u0107 ustawienia urz\u0105dzenia\u201d na stronie 16).","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Nawil\u017cacz nie podgrzewa wody.","rozwiazanie":"Poziom nawil\u017cania jest ustawiony na OFF.  Ustawi\u0107 poziom nawil\u017cania mi\u0119dzy 01 a 10 (patrz rozdzia\u0142 \u201eJak zmieni\u0107 ustawienia urz\u0105dzenia\u201d na stronie 16).","rozwiazywalne_przez_uzytkownika":false}],"konserwacja_czynnosci":null,"numery_seryjne":null},"_links":{"self":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty\/304","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty"}],"about":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/types\/produkty"}],"acf:term":[{"embeddable":true,"taxonomy":"producent","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent\/46"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/26"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/24"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/11"}],"wp:attachment":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media?parent=304"}],"wp:term":[{"taxonomy":"kategoria","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria?post=304"},{"taxonomy":"producent","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent?post=304"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}