 	{"id":306,"date":"2024-12-11T08:34:30","date_gmt":"2024-12-11T08:34:30","guid":{"rendered":"https:\/\/app.medseven.pl\/?post_type=produkty&#038;p=306"},"modified":"2025-12-28T16:52:06","modified_gmt":"2025-12-28T15:52:06","slug":"aparat-do-bezdechu-sennego-resmart-g3-a20-bmc-autocpap","status":"publish","type":"produkty","link":"https:\/\/app.medseven.pl\/index.php\/produkty\/aparat-do-bezdechu-sennego-resmart-g3-a20-bmc-autocpap\/","title":{"rendered":"Aparat do bezdechu sennego RESmart G3 A20 BMC &#8211; autocpap"},"content":{"rendered":"","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"kategoria":[11,24,26],"producent":[],"class_list":["post-306","produkty","type-produkty","status-publish","hentry","kategoria-aparatura-medyczna","kategoria-aparaty-cpap","kategoria-aparaty-autocpap"],"acf":{"kategoria":[11,24,26],"zdjecie_podstawowe":594,"ident":"108663","producent":42,"model":"RESmart G3 A20","opis":"Resmart G3 Auto CPAP to urz\u0105dzenie przeznaczone do leczenia bezdechu sennego z funkcj\u0105 automatycznej regulacji ci\u015bnienia. Inteligentny algorytm, w jaki zosta\u0142 wyposa\u017cony ten nowoczesny sprz\u0119t medyczny, zosta\u0142 tak zaprojektowany, aby nieustannie monitorowa\u0107 przep\u0142yw powietrza w drogach oddechowych pacjenta i w por\u0119 wychwytywa\u0107 wszelkie nieprawid\u0142owo\u015bci, zw\u0142aszcza tak gro\u017ane dla \u017cycia zaburzenia oddychania jak obturacyjny bezdech senny. Na ka\u017cd\u0105 zmian\u0119 w oddechu aparat potrafi automatycznie zareagowa\u0107, odpowiednio dostosowuj\u0105c warto\u015b\u0107 ci\u015bnienia, obni\u017caj\u0105c je lub podwy\u017cszaj\u0105c do konkretnego poziomu, w zale\u017cno\u015bci od potrzeb.\r\n\r\nZintegrowany z aparatem nawil\u017cacz jest bardzo wygodny w u\u017cyciu, poniewa\u017c pozwala na nape\u0142nianie pojemnika wod\u0105 bez konieczno\u015bci jego wyjmowania. W razie potrzeby mo\u017cna jednak bez problemu od\u0142\u0105czy\u0107 nawil\u017cacz do urz\u0105dzenia, u\u0142atwia to prosty, acz solidny zatrzask \u2013 dzi\u0119ki temu czyszczenie pojemnika nie sprawia \u017cadnego k\u0142opotu. Kontrola wilgotno\u015bci odbywa si\u0119 w spos\u00f3b automatyczny. Czujniki, w jakie wyposa\u017cono urz\u0105dzenie, mierz\u0105 zar\u00f3wno wewn\u0119trzn\u0105, jak i zewn\u0119trzn\u0105 temperatur\u0119 powietrza, a nast\u0119pnie dostosowuj\u0105 stopie\u0144 wilgotno\u015bci tak, aby zapobiec jego kondensacji. Ponadto Resmart G3 posiada funkcj\u0119 auto ramp, polegaj\u0105c\u0105 na stopniowym podnoszeniu ci\u015bnienia w celu u\u0142atwienia zasypiania, oraz funkcj\u0119 reslex, \u0142agodz\u0105c\u0105 wydechy i w ten spos\u00f3b podnosz\u0105c\u0105 komfort terapii.","specyfikacja":"<h3 data-start=\"118\" data-end=\"137\">Dane techniczne<\/h3>\r\n<ul data-start=\"139\" data-end=\"1382\">\r\n \t<li data-start=\"139\" data-end=\"208\">\r\n<p data-start=\"141\" data-end=\"208\"><strong data-start=\"141\" data-end=\"159\">Typ urz\u0105dzenia<\/strong>: Auto CPAP (automatyczne dostosowanie ci\u015bnienia)<\/p>\r\n<\/li>\r\n \t<li data-start=\"209\" data-end=\"243\">\r\n<p data-start=\"211\" data-end=\"243\"><strong data-start=\"211\" data-end=\"226\">Tryby pracy<\/strong>: CPAP, Auto CPAP<\/p>\r\n<\/li>\r\n \t<li data-start=\"244\" data-end=\"279\">\r\n<p data-start=\"246\" data-end=\"279\"><strong data-start=\"246\" data-end=\"266\">Zakres ci\u015bnienia<\/strong>: 4\u201320 cm H\u2082O<\/p>\r\n<\/li>\r\n \t<li data-start=\"280\" data-end=\"328\">\r\n<p data-start=\"282\" data-end=\"328\"><strong data-start=\"282\" data-end=\"296\">Czas rampy<\/strong>: 0\u201360 minut, z funkcj\u0105 AutoRamp<\/p>\r\n<\/li>\r\n \t<li data-start=\"329\" data-end=\"390\">\r\n<p data-start=\"331\" data-end=\"390\"><strong data-start=\"331\" data-end=\"349\">Funkcja RESlex<\/strong>: Tak, z trzema poziomami ulgi na wydechu<\/p>\r\n<\/li>\r\n \t<li data-start=\"391\" data-end=\"491\">\r\n<p data-start=\"393\" data-end=\"491\"><strong data-start=\"393\" data-end=\"426\">Funkcja Auto Humidity Control<\/strong>: Tak, zintegrowany nawil\u017cacz z automatyczn\u0105 kontrol\u0105 wilgotno\u015bci<\/p>\r\n<\/li>\r\n \t<li data-start=\"492\" data-end=\"591\">\r\n<p data-start=\"494\" data-end=\"591\"><strong data-start=\"494\" data-end=\"517\">Funkcja pre-heating<\/strong>: Tak, mo\u017cliwo\u015b\u0107 podgrzewania wody w nawil\u017caczu przed rozpocz\u0119ciem terapii<\/p>\r\n<\/li>\r\n \t<li data-start=\"592\" data-end=\"622\">\r\n<p data-start=\"594\" data-end=\"622\"><strong data-start=\"594\" data-end=\"611\">Poziom ha\u0142asu<\/strong>: \u226426 dB(A)<\/p>\r\n<\/li>\r\n \t<li data-start=\"623\" data-end=\"656\">\r\n<p data-start=\"625\" data-end=\"656\"><strong data-start=\"625\" data-end=\"636\">Wymiary<\/strong>: 265 \u00d7 145 \u00d7 114 mm<\/p>\r\n<\/li>\r\n \t<li data-start=\"657\" data-end=\"691\">\r\n<p data-start=\"659\" data-end=\"691\"><strong data-start=\"659\" data-end=\"667\">Waga<\/strong>: 1,7 kg (z nawil\u017caczem)<\/p>\r\n<\/li>\r\n \t<li data-start=\"692\" data-end=\"731\">\r\n<p data-start=\"694\" data-end=\"731\"><strong data-start=\"694\" data-end=\"707\">Zasilanie<\/strong>: 100\u2013240 V AC, 50\/60 Hz<\/p>\r\n<\/li>\r\n \t<li data-start=\"732\" data-end=\"761\">\r\n<p data-start=\"734\" data-end=\"761\"><strong data-start=\"734\" data-end=\"748\">Pob\u00f3r mocy<\/strong>: maks. 2,5 A<\/p>\r\n<\/li>\r\n \t<li data-start=\"762\" data-end=\"817\">\r\n<p data-start=\"764\" data-end=\"817\"><strong data-start=\"764\" data-end=\"774\">Pami\u0119\u0107<\/strong>: Karta SD (365 dni danych terapeutycznych)<\/p>\r\n<\/li>\r\n \t<li data-start=\"818\" data-end=\"958\">\r\n<p data-start=\"820\" data-end=\"833\"><strong data-start=\"820\" data-end=\"832\">\u0141\u0105czno\u015b\u0107<\/strong>:<\/p>\r\n\r\n<ul data-start=\"836\" data-end=\"958\">\r\n \t<li data-start=\"836\" data-end=\"843\">\r\n<p data-start=\"838\" data-end=\"843\">Wi-Fi<\/p>\r\n<\/li>\r\n \t<li data-start=\"846\" data-end=\"857\">\r\n<p data-start=\"848\" data-end=\"857\">Bluetooth<\/p>\r\n<\/li>\r\n \t<li data-start=\"860\" data-end=\"882\">\r\n<p data-start=\"862\" data-end=\"882\">iCode QR \/ iCode QR+<\/p>\r\n<\/li>\r\n \t<li data-start=\"885\" data-end=\"927\">\r\n<p data-start=\"887\" data-end=\"927\">Aplikacja mobilna PAP Link (iOS\/Android)<\/p>\r\n<\/li>\r\n \t<li data-start=\"930\" data-end=\"958\">\r\n<p data-start=\"932\" data-end=\"958\">Platforma chmurowa BMCares<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"959\" data-end=\"1089\">\r\n<p data-start=\"961\" data-end=\"986\"><strong data-start=\"961\" data-end=\"985\">Opcjonalne akcesoria<\/strong>:<\/p>\r\n\r\n<ul data-start=\"989\" data-end=\"1089\">\r\n \t<li data-start=\"989\" data-end=\"1002\">\r\n<p data-start=\"991\" data-end=\"1002\">Zestaw SpO\u2082<\/p>\r\n<\/li>\r\n \t<li data-start=\"1005\" data-end=\"1025\">\r\n<p data-start=\"1007\" data-end=\"1025\">Modu\u0142 Wi-Fi \/ GPRS<\/p>\r\n<\/li>\r\n \t<li data-start=\"1028\" data-end=\"1073\">\r\n<p data-start=\"1030\" data-end=\"1073\">Zintegrowany podgrzewany przew\u00f3d powietrzny<\/p>\r\n<\/li>\r\n \t<li data-start=\"1076\" data-end=\"1089\">\r\n<p data-start=\"1078\" data-end=\"1089\">Filtr PM2.5<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"1090\" data-end=\"1252\">\r\n<p data-start=\"1092\" data-end=\"1115\"><strong data-start=\"1092\" data-end=\"1114\">Wbudowane czujniki<\/strong>:<\/p>\r\n\r\n<ul data-start=\"1118\" data-end=\"1252\">\r\n \t<li data-start=\"1118\" data-end=\"1169\">\r\n<p data-start=\"1120\" data-end=\"1169\">Monitorowanie temperatury i wilgotno\u015bci powietrza<\/p>\r\n<\/li>\r\n \t<li data-start=\"1172\" data-end=\"1200\">\r\n<p data-start=\"1174\" data-end=\"1200\">Wykrywanie przecieku maski<\/p>\r\n<\/li>\r\n \t<li data-start=\"1203\" data-end=\"1252\">\r\n<p data-start=\"1205\" data-end=\"1252\">Wykrywanie bezdechu centralnego i obturacyjnego<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"1253\" data-end=\"1382\">\r\n<p data-start=\"1255\" data-end=\"1276\"><strong data-start=\"1255\" data-end=\"1275\">Funkcje alarmowe<\/strong>:<\/p>\r\n\r\n<ul data-start=\"1279\" data-end=\"1382\">\r\n \t<li data-start=\"1279\" data-end=\"1312\">\r\n<p data-start=\"1281\" data-end=\"1312\">Powiadomienia o przecieku maski<\/p>\r\n<\/li>\r\n \t<li data-start=\"1315\" data-end=\"1346\">\r\n<p data-start=\"1317\" data-end=\"1346\">Powiadomienia o zdj\u0119tej masce<\/p>\r\n<\/li>\r\n \t<li data-start=\"1349\" data-end=\"1382\">\r\n<p data-start=\"1351\" data-end=\"1382\">Powiadomienia o braku zasilania<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"1384\" data-end=\"1405\">Zawarto\u015b\u0107 zestawu<\/h3>\r\n<ul data-start=\"1407\" data-end=\"1592\">\r\n \t<li data-start=\"1407\" data-end=\"1439\">\r\n<p data-start=\"1409\" data-end=\"1439\">Aparat CPAP BMC RESmart G3 A20<\/p>\r\n<\/li>\r\n \t<li data-start=\"1440\" data-end=\"1464\">\r\n<p data-start=\"1442\" data-end=\"1464\">Zintegrowany nawil\u017cacz<\/p>\r\n<\/li>\r\n \t<li data-start=\"1465\" data-end=\"1485\">\r\n<p data-start=\"1467\" data-end=\"1485\">Przew\u00f3d powietrzny<\/p>\r\n<\/li>\r\n \t<li data-start=\"1486\" data-end=\"1496\">\r\n<p data-start=\"1488\" data-end=\"1496\">Karta SD<\/p>\r\n<\/li>\r\n \t<li data-start=\"1497\" data-end=\"1523\">\r\n<p data-start=\"1499\" data-end=\"1523\">Wymienne filtry (2 szt.)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1524\" data-end=\"1534\">\r\n<p data-start=\"1526\" data-end=\"1534\">Zasilacz<\/p>\r\n<\/li>\r\n \t<li data-start=\"1535\" data-end=\"1551\">\r\n<p data-start=\"1537\" data-end=\"1551\">Torba podr\u00f3\u017cna<\/p>\r\n<\/li>\r\n \t<li data-start=\"1552\" data-end=\"1572\">\r\n<p data-start=\"1554\" data-end=\"1572\">Instrukcja obs\u0142ugi<\/p>\r\n<\/li>\r\n \t<li data-start=\"1573\" data-end=\"1592\">\r\n<p data-start=\"1575\" data-end=\"1592\">Karta gwarancyjna<\/p>\r\n<\/li>\r\n<\/ul>","instrukcje":516,"media":"","wideo":[{"tytul":"Poruszanie si\u0119 po menu","wideo":1135},{"tytul":"Menu Kliniczne","wideo":1136},{"tytul":"Menu kliniczne - ustawienia ","wideo":1137}],"kody":[{"kod_serwisowy":"Awaria Zasilania!!!","rozwiazanie":"Je\u015bli urz\u0105dzenie dostarcza powietrze i w tym czasie zostanie\r\nprzypadkowo roz\u0142\u0105czone od \u017ar\u00f3d\u0142a zasilania, to w\u0142\u0105czy si\u0119 brz\u0119czyk.\r\nUwaga:\r\n(1) Ten alarm nie zadzia\u0142a w przypadku awarii zasilania, je\u015bli\r\nurz\u0105dzenie b\u0119dzie w stanie czuwania.\r\n(2) W czasie awarii zasilania nie wy\u015bwietlaj\u0105 si\u0119 \u017cadne komunikaty\r\nalarmowe na ekranie","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"B\u0142\u0105d Urz\u0105dzenia!!!","rozwiazanie":"Brz\u0119czyk oznajmi brak wyp\u0142ywu strumienia powietrza z urz\u0105dzenia.\r\nNa ekranie wy\u015bwietli si\u0119 komunikat \u2015B\u0142\u0105d Urz\u0105dzenia!!!","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Przeciek!!","rozwiazanie":"Przy w\u0142\u0105czonym dostarczaniu powietrza, brz\u0119czyk odezwie si\u0119 je\u015bli szybko\u015b\u0107 ucieczki powietrza przekroczy 150 L\/min. Na ekranie wy\u015bwietli si\u0119 komunikat : Przeciek!!\r\nNieszczelna maska oddechowa.  Ustawi\u0107 paski mocuj\u0105ce tak, aby maska szczelnie przylega\u0142a. W razie potrzeby: wymieni\u0107 uszkodzon\u0105 mask\u0119.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Niski Napi\u0119cie Wej\u015bciowe!!","rozwiazanie":"Je\u015bli zamiast zasilacza sieciowego stosowany jest akumulator, to\r\nprzy niskim stanie na\u0142adowania zabrzmi brz\u0119czyk. Na ekranie\r\nwy\u015bwietli si\u0119 komunikat : Niski Napi\u0119cie Wej\u015bciowe!!","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Awaria Nawil\u017cacza!!","rozwiazanie":"Je\u015bli nawil\u017cacz ulegnie awarii w trakcie pracy, to zabrzmi brz\u0119czyk.\r\nNa ekranie wy\u015bwietli si\u0119 komunikat : Awaria Nawil\u017cacza!!","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Prosz\u0119 Zmieni\u0107 Filtr!","rozwiazanie":"Przy w\u0142\u0105czonym alarmowaniu zu\u017cycia filtra, brz\u0119czyk oznacza \u017ce\r\nokres u\u017cytkowania filtra przekroczy\u0142 p\u00f3\u0142 roku. \r\nNa ekranie wy\u015bwietli si\u0119 komunikat : Prosz\u0119 Zmieni\u0107 Filtr!","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Karta SD Pe\u0142na!","rozwiazanie":"Na ekranie wy\u015bwietli si\u0119 \u2015Karta SD Pe\u0142na, je\u015bli jest zape\u0142niona do maksimum pojemno\u015bci","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"W\u0142\u00f3\u017c Ponownie Kart\u0119 SD!","rozwiazanie":"Na ekranie wy\u015bwietli si\u0119 komunikat : W\u0142\u00f3\u017c Ponownie Kart\u0119 SD! ,\r\nje\u015bli karta SD nie dzia\u0142a poprawnie.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Woda w masce","rozwiazanie":"1. W trakcie pracy nawil\u017cacza, je\u015bli temperatura otoczenia jest niska, nawil\u017cone powietrze skrapla si\u0119 w zimnym przewodzie i masce. \r\n2. Obni\u017cy\u0107 ustawienie wilgotno\u015bci albo podwy\u017cszy\u0107 temperatur\u0119 w pomieszczeniu. \r\n3. Umie\u015bci\u0107 przew\u00f3d pod ko\u0142dr\u0105 albo u\u017cy\u0107 os\u0142ony do przewodu.\r\n4. Lu\u017ano powiesi\u0107 przew\u00f3d, przy czym najni\u017cszy punkt przewodu powinien si\u0119 znale\u017a\u0107 ni\u017cej ni\u017c g\u0142owa pacjenta","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Urz\u0105dzenie jest na czuwaniu i nie chce si\u0119 uruchomi\u0107","rozwiazanie":"System operacyjny wymaga ustawienia albo ponownego uruchomienia  Wyj\u0105\u0107 wtyczk\u0119 z gniazdka zasilania i po 20 sekundach w\u0142o\u017cy\u0107 z powrotem","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Po w\u0142\u0105czeniu urz\u0105dzenia, ekran wy\u015bwietla nieregularnie albo nie pokazuje nic","rozwiazanie":"System operacyjny wymaga ustawienia albo ponownego uruchomienia  Wyj\u0105\u0107 wtyczk\u0119 z gniazdka zasilania i po 20 sekundach w\u0142o\u017cy\u0107 z powrotem","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Urz\u0105dzenie wytwarza bardzo niskie ci\u015bnienie","rozwiazanie":"Wlot powietrza na urz\u0105dzeniu mo\u017ce by\u0107 zaczopowany  \r\n1. Wymieni\u0107 filtr powietrza (zob. 15.6 Wymiana Filtra Powietrza) i wyczy\u015bci\u0107 wlot powietrza. Sprawdzi\u0107 wlot powietrza.\r\n2. Przypadkowo zmieniono ci\u015bnienie terapeutyczne. Skontaktowa\u0107 si\u0119 z lekarzem.\r\n3. Przy w\u0142\u0105czonej funkcji narastania, dochodzenie do ci\u015bnienia terapeutycznego trwa d\u0142u\u017cej. To normalne  W razie konieczno\u015bci, wy\u0142\u0105czy\u0107 funkcj\u0119 narastania albo ustawi\u0107 kr\u00f3tszy czas narastania.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Nawr\u00f3t symptom\u00f3w obturacyjnego bezdechu sennego","rozwiazanie":"Prawdopodobnie wynika to z faktu, \u017ce pacjent \u015bpi z otwartymi ustami, powietrze pod ci\u015bnieniem wydostaje si\u0119 przez usta, powoduj\u0105c niedro\u017cno\u015b\u0107 g\u00f3rnych dr\u00f3g oddechowych  \r\nZastosowa\u0107 pasek podtrzymuj\u0105cy brod\u0119, \u017ceby usta nie otwiera\u0142y si\u0119 w czasie snu, albo zastosowa\u0107 mask\u0119 ustno-nosow\u0105. Wi\u0119cej informacji dostarczy lekarz","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Powietrze dostarczane przez urz\u0105dzenie jest zbyt ciep\u0142e","rozwiazanie":"Wlot powietrza do urz\u0105dzenia mo\u017ce by\u0107 cz\u0119\u015bciowo zaczopowany, przez co niewystarczaj\u0105ca ilo\u015b\u0107 wp\u0142ywa do urz\u0105dzenia  \r\n1. Wymieni\u0107 filtr powietrza (zob. 15.6 Wymiana Filtra Powietrza) i wyczy\u015bci\u0107 wlot powietrza.\r\n2. Urz\u0105dzenie umie\u015bci\u0107 w miejscu o swobodnym przep\u0142ywie powietrza. Od \u015bcian, zas\u0142on lub innych obiekt\u00f3w musi je oddziela\u0107 przynajmniej 20 centymetr\u00f3w wolnej przestrzeni.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Urz\u0105dzenie po w\u0142\u0105czeniu nie dzia\u0142a","rozwiazanie":"1. W\u0142\u0105czona funkcja w\u0142 \/ wy\u0142 . Wykona\u0107 kilka g\u0142\u0119bokich oddech\u00f3w z za\u0142o\u017cona mask\u0105 i urz\u0105dzenie uruchomi si\u0119 automatycznie  \r\n2. Zasilanie jest nieprawid\u0142owo pod\u0142\u0105czone  Sprawdzi\u0107 po\u0142\u0105czenie kabla zasilania, zasilacza sieciowego i urz\u0105dzenia  \r\n3. Brak napi\u0119cia. Sprawdzi\u0107 czy w instalacji jest zasilanie np. przez w\u0142\u0105czenie \u015bwiat\u0142a. \r\n4. Je\u015bli to przepalony bezpiecznik, to trzeba odda\u0107 dostawcy sprz\u0119tu do naprawy \r\n5. Nie udaje si\u0119 znale\u017a\u0107 przyczyny  Skontaktowa\u0107 si\u0119 z dostawc\u0105 sprz\u0119tu","rozwiazywalne_przez_uzytkownika":false}],"konserwacja_czynnosci":null,"numery_seryjne":null},"_links":{"self":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty\/306","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty"}],"about":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/types\/produkty"}],"acf:term":[{"embeddable":true,"taxonomy":"producent","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent\/42"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/26"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/24"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/11"}],"wp:attachment":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media?parent=306"}],"wp:term":[{"taxonomy":"kategoria","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria?post=306"},{"taxonomy":"producent","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent?post=306"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}