 	{"id":750,"date":"2025-07-17T10:47:30","date_gmt":"2025-07-17T08:47:30","guid":{"rendered":"https:\/\/app.medseven.pl\/?post_type=produkty&#038;p=750"},"modified":"2025-08-02T23:07:06","modified_gmt":"2025-08-02T21:07:06","slug":"respirator-prismavent50-c-z-bateria-wewnetrzna-wm30690-1110-s","status":"publish","type":"produkty","link":"https:\/\/app.medseven.pl\/index.php\/produkty\/respirator-prismavent50-c-z-bateria-wewnetrzna-wm30690-1110-s\/","title":{"rendered":"Respirator prismaVENT50-C z bateri\u0105 wewn\u0119trzn\u0105"},"content":{"rendered":"","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":false},"kategoria":[11,15,16,17],"producent":[],"class_list":["post-750","produkty","type-produkty","status-publish","hentry","kategoria-aparatura-medyczna","kategoria-respiratory","kategoria-respiratory-inwazyjne","kategoria-respiratory-nieinwazyjne"],"acf":{"kategoria":[11,15,16,17],"zdjecie_podstawowe":893,"ident":"109589","producent":41,"model":"Prisma VENT50-C","opis":"<p data-start=\"0\" data-end=\"311\"><strong data-start=\"0\" data-end=\"29\">L\u00f6wenstein PRISMA VENT 50<\/strong> to zaawansowany respirator nieinwazyjny i inwazyjny, zaprojektowany do terapii wentylacyjnej u pacjent\u00f3w z przewlek\u0142\u0105 niewydolno\u015bci\u0105 oddechow\u0105. Pochodzi z serii urz\u0105dze\u0144 PRISMA VENT renomowanej niemieckiej firmy L\u00f6wenstein Medical, znanej z wysokiej jako\u015bci technologii medycznych.<\/p>\r\n\r\n<h2><strong><a href=\"https:\/\/prismavent50c.medseven.pl\/\">Wejd\u017a na stron\u0119 produktow\u0105 <\/a>\r\n<\/strong><\/h2>\r\n<a href=\"https:\/\/prismavent50c.medseven.pl\/\"><img class=\"alignnone wp-image-894 size-medium\" src=\"https:\/\/app.medseven.pl\/wp-content\/uploads\/2025\/07\/cats-300x172.jpg\" alt=\"\" width=\"300\" height=\"172\" \/><\/a>\r\n\r\n<strong data-start=\"572\" data-end=\"591\">Kluczowe cechy:<\/strong>\r\n<ul data-start=\"593\" data-end=\"1388\">\r\n \t<li data-start=\"593\" data-end=\"701\">\r\n<p data-start=\"595\" data-end=\"618\"><strong data-start=\"595\" data-end=\"616\">Tryby wentylacji:<\/strong><\/p>\r\n\r\n<ul data-start=\"621\" data-end=\"701\">\r\n \t<li data-start=\"621\" data-end=\"629\">\r\n<p data-start=\"623\" data-end=\"629\">CPAP<\/p>\r\n<\/li>\r\n \t<li data-start=\"632\" data-end=\"652\">\r\n<p data-start=\"634\" data-end=\"652\">BiLevel S, ST, T<\/p>\r\n<\/li>\r\n \t<li data-start=\"655\" data-end=\"665\">\r\n<p data-start=\"657\" data-end=\"665\">AutoST<\/p>\r\n<\/li>\r\n \t<li data-start=\"668\" data-end=\"701\">\r\n<p data-start=\"670\" data-end=\"701\">IVAPS i inne tryby wspomagaj\u0105ce<\/p>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n \t<li data-start=\"703\" data-end=\"815\">\r\n<p data-start=\"705\" data-end=\"815\"><strong data-start=\"705\" data-end=\"745\">Wentylacja inwazyjna i nieinwazyjna:<\/strong><br data-start=\"745\" data-end=\"748\" \/>Mo\u017cliwo\u015b\u0107 stosowania zar\u00f3wno z mask\u0105, jak i rurk\u0105 tracheotomijn\u0105.<\/p>\r\n<\/li>\r\n \t<li data-start=\"817\" data-end=\"923\">\r\n<p data-start=\"819\" data-end=\"923\"><strong data-start=\"819\" data-end=\"857\">Szeroki zakres ustawie\u0144 ci\u015bnienia:<\/strong><br data-start=\"857\" data-end=\"860\" \/>Umo\u017cliwia precyzyjne dostosowanie parametr\u00f3w terapeutycznych.<\/p>\r\n<\/li>\r\n \t<li data-start=\"925\" data-end=\"1020\">\r\n<p data-start=\"927\" data-end=\"1020\"><strong data-start=\"927\" data-end=\"955\">Kolorowy ekran dotykowy:<\/strong><br data-start=\"955\" data-end=\"958\" \/>Intuicyjne menu, czytelna prezentacja danych, \u0142atwa obs\u0142uga.<\/p>\r\n<\/li>\r\n \t<li data-start=\"1022\" data-end=\"1154\">\r\n<p data-start=\"1024\" data-end=\"1154\"><strong data-start=\"1024\" data-end=\"1048\">Opcje monitorowania:<\/strong><br data-start=\"1048\" data-end=\"1051\" \/>Urz\u0105dzenie zbiera dane oddechowe i zapewnia raportowanie (dane mo\u017cna przesy\u0142a\u0107 i analizowa\u0107 zdalnie).<\/p>\r\n<\/li>\r\n \t<li data-start=\"1156\" data-end=\"1267\">\r\n<p data-start=\"1158\" data-end=\"1267\"><strong data-start=\"1158\" data-end=\"1207\">Zintegrowany modu\u0142 SpO\u2082 i opcjonalna turbina:<\/strong><br data-start=\"1207\" data-end=\"1210\" \/>Umo\u017cliwia pe\u0142niejsze monitorowanie parametr\u00f3w pacjenta.<\/p>\r\n<\/li>\r\n \t<li data-start=\"1269\" data-end=\"1388\">\r\n<p data-start=\"1271\" data-end=\"1388\"><strong data-start=\"1271\" data-end=\"1299\">Alarmy i bezpiecze\u0144stwo:<\/strong><br data-start=\"1299\" data-end=\"1302\" \/>Zaawansowany system alarm\u00f3w zapewniaj\u0105cy natychmiastow\u0105 reakcj\u0119 na nieprawid\u0142owo\u015bci.<\/p>\r\n<\/li>\r\n<\/ul>\r\n<h3 data-start=\"1395\" data-end=\"1426\"><strong data-start=\"1399\" data-end=\"1426\">Zastosowanie kliniczne:<\/strong><\/h3>\r\n<ul data-start=\"1428\" data-end=\"1651\">\r\n \t<li data-start=\"1428\" data-end=\"1475\">\r\n<p data-start=\"1430\" data-end=\"1475\">Przewlek\u0142a obturacyjna choroba p\u0142uc (POChP)<\/p>\r\n<\/li>\r\n \t<li data-start=\"1476\" data-end=\"1521\">\r\n<p data-start=\"1478\" data-end=\"1521\">Neuromi\u0119\u015bniowe choroby uk\u0142adu oddechowego<\/p>\r\n<\/li>\r\n \t<li data-start=\"1522\" data-end=\"1550\">\r\n<p data-start=\"1524\" data-end=\"1550\">Hipowentylacja o\u015brodkowa<\/p>\r\n<\/li>\r\n \t<li data-start=\"1551\" data-end=\"1610\">\r\n<p data-start=\"1553\" data-end=\"1610\">Zesp\u00f3\u0142 bezdechu sennego z zaawansowanym niedotlenieniem<\/p>\r\n<\/li>\r\n \t<li data-start=\"1611\" data-end=\"1651\">\r\n<p data-start=\"1613\" data-end=\"1651\">Wsparcie oddechowe po hospitalizacji<\/p>\r\n<\/li>\r\n<\/ul>","specyfikacja":"<p data-start=\"164\" data-end=\"357\"><strong data-start=\"164\" data-end=\"197\">Wymiary (szer. \u00d7 wys. \u00d7 g\u0142.):<\/strong> 21,8 \u00d7 17,5 \u00d7 21,8 cm<br data-start=\"219\" data-end=\"222\" \/><strong data-start=\"222\" data-end=\"242\">Waga urz\u0105dzenia:<\/strong> 2,5 kg<br data-start=\"249\" data-end=\"252\" \/><strong data-start=\"252\" data-end=\"286\">Waga akumulatora wewn\u0119trznego:<\/strong> 0,63 kg<br data-start=\"294\" data-end=\"297\" \/><strong data-start=\"297\" data-end=\"343\">Maksymalny przep\u0142yw powietrza przy 20 hPa:<\/strong> &gt; 220 l\/min<\/p>\r\n<p data-start=\"359\" data-end=\"557\"><strong data-start=\"359\" data-end=\"402\">Czas pracy na akumulatorze wewn\u0119trznym:<\/strong><br data-start=\"402\" data-end=\"405\" \/>Przy ustawieniach: tryb T, 20 oddech\u00f3w\/min, Ti = 1 s, PEEP = 4 hPa, Vt = 800 ml, wentylacja bierna (R = 5 hPa\/(l\/s), C = 50 ml\/hPa):<br data-start=\"537\" data-end=\"540\" \/>ponad 10 godzin<\/p>\r\n<p data-start=\"559\" data-end=\"769\"><strong data-start=\"559\" data-end=\"585\">Zakres ci\u015bnienia IPAP:<\/strong> 4\u201350 hPa<br data-start=\"594\" data-end=\"597\" \/><strong data-start=\"597\" data-end=\"623\">Zakres ci\u015bnienia PEEP:<\/strong> 4\u201325 hPa (system przeciekowy), 0\u201325 hPa (system zastawkowy)<br data-start=\"683\" data-end=\"686\" \/><strong data-start=\"686\" data-end=\"712\">Cz\u0119stotliwo\u015b\u0107 oddechu:<\/strong> 0\u201360 oddech\u00f3w\/min<br data-start=\"730\" data-end=\"733\" \/><strong data-start=\"733\" data-end=\"755\">Obj\u0119to\u015b\u0107 docelowa:<\/strong> 100\u20132000 ml<\/p>\r\n<p data-start=\"771\" data-end=\"919\"><strong data-start=\"771\" data-end=\"805\">Czu\u0142o\u015b\u0107 triggera (wyzwalacza):<\/strong><br data-start=\"805\" data-end=\"808\" \/>Wdech: 1 (niska czu\u0142o\u015b\u0107) do 8 (wysoka czu\u0142o\u015b\u0107)<br data-start=\"854\" data-end=\"857\" \/>Wydech: od 95% do 5% przep\u0142ywu maksymalnego, regulacja co 5%<\/p>\r\n<p data-start=\"921\" data-end=\"1039\"><strong data-start=\"921\" data-end=\"952\">Pr\u0119dko\u015b\u0107 wzrostu ci\u015bnienia:<\/strong><br data-start=\"952\" data-end=\"955\" \/>Poziom 1: 100 hPa\/s<br data-start=\"974\" data-end=\"977\" \/>Poziom 2: 80 hPa\/s<br data-start=\"995\" data-end=\"998\" \/>Poziom 3: 50 hPa\/s<br data-start=\"1016\" data-end=\"1019\" \/>Poziom 4: 20 hPa\/s<\/p>\r\n<p data-start=\"1041\" data-end=\"1158\"><strong data-start=\"1041\" data-end=\"1071\">Pr\u0119dko\u015b\u0107 spadku ci\u015bnienia:<\/strong><br data-start=\"1071\" data-end=\"1074\" \/>Poziom 1: 100 hPa\/s<br data-start=\"1093\" data-end=\"1096\" \/>Poziom 2: 80 hPa\/s<br data-start=\"1114\" data-end=\"1117\" \/>Poziom 3: 50 hPa\/s<br data-start=\"1135\" data-end=\"1138\" \/>Poziom 4: 20 hPa\/s<\/p>\r\n<p data-start=\"1160\" data-end=\"1269\"><strong data-start=\"1160\" data-end=\"1183\">Obj\u0119to\u015b\u0107 oddechowa:<\/strong> 100\u20132000 ml<br data-start=\"1195\" data-end=\"1198\" \/><strong data-start=\"1198\" data-end=\"1255\">Maksymalny przep\u0142yw tlenu (z zasilania zewn\u0119trznego):<\/strong> do 15 l\/min<\/p>\r\n<p data-start=\"1271\" data-end=\"1369\"><strong data-start=\"1271\" data-end=\"1301\">Dost\u0119pne tryby wentylacji:<\/strong><br data-start=\"1301\" data-end=\"1304\" \/>CPAP<br data-start=\"1308\" data-end=\"1311\" \/>T<br data-start=\"1312\" data-end=\"1315\" \/>ST<br data-start=\"1317\" data-end=\"1320\" \/>autoST<br data-start=\"1326\" data-end=\"1329\" \/>S<br data-start=\"1330\" data-end=\"1333\" \/>aPCV<br data-start=\"1337\" data-end=\"1340\" \/>PCV<br data-start=\"1343\" data-end=\"1346\" \/>PSV<br data-start=\"1349\" data-end=\"1352\" \/>MPVp<br data-start=\"1356\" data-end=\"1359\" \/>MPVv<br data-start=\"1363\" data-end=\"1366\" \/>HFT<\/p>","instrukcje":889,"media":[893,894,895],"wideo":null,"kody":[{"kod_serwisowy":"Bezdech","rozwiazanie":"Brak oddechu spontanicznego w obr\u0119bie ustawionego czasu.\r\nPoprosi\u0107 lekarza prowadz\u0105cego o sprawdzenie ustawie\u0144.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Wys. ci\u015bn.","rozwiazanie":"Zosta\u0142o przekroczone ci\u015bnienie maksymalne.\r\nPoprosi\u0107 lekarza prowadz\u0105cego o sprawdzenie ustawie\u0144.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"Nisk. ci\u015bn.","rozwiazanie":"1.  Nie zosta\u0142o osi\u0105gni\u0119te minimalne ci\u015bnienie\r\nterapeutyczne. Wyczy\u015bci\u0107lub wymieni\u0107 zanieczyszczone filtry.\r\n\r\n2. Doj\u015bcie oddechowe jest nieszczelne. Ponownie ustawi\u0107 doj\u015bcie\r\noddechowe.\r\n\r\n3. Uszkodzone doj\u015bcie oddechowe. Wymieni\u0107 doj\u015bcie oddechowe.\r\n\r\n4. Nielogiczne ustawienia. Poprosi\u0107 lekarza prowadz\u0105cego\r\no sprawdzenie ustawie\u0144. ","rozwiazywalne_przez_uzytkownika":true},{"kod_serwisowy":"Konieczny serwis. Skontaktowa\u0107 si\u0119 z dostawc\u0105 \/ personelem medycznotechnicznym.","rozwiazanie":"B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"552 - Bateria uszkodzona","rozwiazanie":"Wymie\u0144 bateri\u0119. B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"203 - B\u0142\u0105d czujnik\u00f3w","rozwiazanie":"Sprawd\u017a uk\u0142ad, usu\u0144 mo\u017cliwe blokady, wymie\u0144 uk\u0142ad. (Mo\u017cliwo\u015b\u0107 zalania respiratora.)","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"202 - B\u0142\u0105d turbiny","rozwiazanie":"Wymie\u0144 turbin\u0119. B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"254 - B\u0142\u0105d przep\u0142ywu","rozwiazanie":"Awaria czujnika przep\u0142ywu. Wymie\u0144 p\u0142yt\u0119 g\u0142\u00f3wn\u0105. B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"255 - Awaria zasilania","rozwiazanie":"Awaria p\u0142yty g\u0142\u00f3wnej. Wymie\u0144 p\u0142yt\u0119 g\u0142\u00f3wn\u0105. B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"256 - Awaria zasilania","rozwiazanie":"Awaria p\u0142yty g\u0142\u00f3wnej. Wymie\u0144 p\u0142yt\u0119 g\u0142\u00f3wn\u0105. B\u0142\u0105d techniczny, kt\u00f3ry mo\u017ce zosta\u0107 usuni\u0119ty wy\u0142\u0105cznie przez autoryzowany serwis specjalistyczny. Przekaza\u0107 urz\u0105dzenie do naprawy.","rozwiazywalne_przez_uzytkownika":false},{"kod_serwisowy":"301 - Wymie\u0144 filtr","rozwiazanie":"Nale\u017cy wymieni\u0107 bia\u0142y filtr na tyle urz\u0105dzenia, znajduj\u0105cy si\u0119 pod czarnym filtrem g\u0105bkowym. Czarny filtr nale\u017cy obmy\u0107 pod bie\u017c\u0105c\u0105 wod\u0105 i osuszy\u0107. \r\nNast\u0119pnie nale\u017cy skasowa\u0107 licznik filtra w urz\u0105dzeniu. Wchodzimy do zak\u0142adki SYSTEM, a nast\u0119pnie pod Timer filtra, nale\u017cy nacisn\u0105\u0107 ZRESETUJ.","rozwiazywalne_przez_uzytkownika":false}],"konserwacja_czynnosci":[{"czynnosc":"Wymiana baterii","interwal_czasowy":1400}],"numery_seryjne":[{"numery_seryjny":"4009900550284","dodatkowe_numery":null},{"numery_seryjny":"1234566","dodatkowe_numery":null}]},"_links":{"self":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty\/750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/produkty"}],"about":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/types\/produkty"}],"acf:attachment":[{"embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media\/895"},{"embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media\/894"},{"embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media\/893"}],"acf:term":[{"embeddable":true,"taxonomy":"producent","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent\/41"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/17"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/16"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/15"},{"embeddable":true,"taxonomy":"kategoria","href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria\/11"}],"wp:attachment":[{"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/media?parent=750"}],"wp:term":[{"taxonomy":"kategoria","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/kategoria?post=750"},{"taxonomy":"producent","embeddable":true,"href":"https:\/\/app.medseven.pl\/index.php\/wp-json\/wp\/v2\/producent?post=750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}